Issue link: https://resources.pcb.cadence.com/i/1180526
PSpice A/D User Guide Setting up analyses and starting simulation October 2019 447 Product Version 17.4-2019 © 2022 All Rights Reserved. ■ If one or more sections of the split part are missing, the pins of the missing part are treated as unconnected and a warning message is displayed. ■ If one or more sections of a split part are instantiated more than one time, netlist is not created and an error message is displayed. This error is flagged only if the sec property from symbol.css has the same value for one or more parts of different instances. Packaged Design If you open a packaged design and run PSpice netlister, it will copy the $LOCATION values if they are unique and the RefDes prefix are same. If the prefix for RefDes for both $PSPICE_LOCATION and $LOCATION are different and the values do not exist, PSpice netlister will use the same prefix for both $LOCATION and $PSPICE_LOCATION. However, if the prefixes are same and the $LOCATION attributes are not unique, an error will be generated. The following tables shows sample values of $LOCATION and $PSPICE_LOCATION when PSpice netlister is run. Condition $PSPICE_LOCATION Example $LOCATION Example Values do not exist and prefixes are same, C C1 C1 Values do not exist and prefixes are different, say X and C X1 C1 LOCATION value exists and prefixes are X and C X1 C1 LOCATION value exists and prefixes are same, C C1 C1