PSpice User Guide

PSpice User Guide

Issue link: https://resources.pcb.cadence.com/i/1180526

Contents of this Issue

Navigation

Page 818 of 884

PSpice User Guide Bias Point Display October 2019 819 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. ■ A given voltage or current source can have a different DC value and initial transient value at TIME=0. This means that the initial transient bias calculation can be different from the DC (small-signal) bias point. ■ For a Transient analysis, only the initial transient bias values are shown. Displaying bias point values You have the option of enabling the display of bias information for all nets, pins and power sources in the circuit, or of enabling only selected nets, pins and power sources. You can also disable bias point display all together for situations such as large digital designs where the legibility of the schematic might be reduced.

Articles in this issue

view archives of PSpice User Guide - PSpice User Guide