PSpice User Guide DC analyses October 2019 483 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. If Bias Point is enabled, you can suppress the reporting of the bias point analog and digital node values, as follows: 1. Under the Options tab in the Simulation Settings dialog box, select Output file in the Category box. 2. Uncheck the box for Bias point node voltages (NOBIAS).