Issue link: https://resources.pcb.cadence.com/i/1180526
PSpice User Guide Simulation examples October 2019 107 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. To add a time-domain voltage stimulus in Design Entry HDL 1. In Design Entry HDL, choose PSpice Simulator – Probes – View Probes. The Probes dialog box appears. 2. Click Remove All. 3. Click Close to close the Probes dialog box. 4. Place a VSTIM part (from the PSpice library SOURCSTM) as shown in Figure 2-14. 5. From the Text menu, choose Attributes. 6. Click on the VSTIM part to display the Attributes dialog box. 7. Change the value of the IMPLEMENTATION property to SINE. This specifies the name of the stimulus. 8. Click OK to close the Attributes dialog box. 9. From the File menu, choose Save to save the design. To set up the stimulus 1. Select the VSTIM part (V3). 2. In Capture, choose Edit - PSpice Stimulus. In Design Entry HDL, right-click and choose Edit Stimulus. The New Stimulus dialog box appears. 3. In the New Stimulus dialog box, type SINE.