PSpice User Guide

PSpice User Guide

Issue link: https://resources.pcb.cadence.com/i/1180526

Contents of this Issue

Navigation

Page 476 of 884

PSpice User Guide DC analyses October 2019 477 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. 4. Define the DC specification as follows: 5. Click OK twice to exit the dialog boxes. Note: If you are planning to run an AC or transient analysis in addition to a DC analysis, see the following: ❑ Using time-based stimulus parts with AC and DC properties on page 175 for other source symbols that you can use. ❑ Using VSRC or ISRC parts on page 176 to find out how to specify the TRAN attribute for a time-based input signal when using VSRC or ISRC symbols. Nested DC sweeps A second sweep variable can be selected after a primary sweep value has been specified in the DC Sweep dialog box. When you specify a secondary sweep variable, it forms the outer loop for the Table 9-3 Set this attribute... To this value... DC DC_level where DC_level is in volts or amps (units are optional).

Articles in this issue

view archives of PSpice User Guide - PSpice User Guide