PSpice User Guide

PSpice User Guide

Issue link: https://resources.pcb.cadence.com/i/1180526

Contents of this Issue

Navigation

Page 544 of 884

PSpice User Guide Transient analysis October 2019 545 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. a. From the PSpice menu, choose Edit Simulation Profile to display the Simulation Settings dialog box. b. In the Simulation Settings dialog box, select the Configuration Files tab. c. Click Include in the Category field to display the Include files list. d. Enter the file name specified in step 2. e. If the stimulus specifications are for only for the current profile, click the Add to Profile button. For local use in the current design, click the Add to Design button. For global use by any design, use Add as Global instead. f. Click OK. 5. Modify either the stimulus instances in the schematic or symbols in the symbol library to reference the new stimulus specification. 6. Associate the transient stimulus specification to a stimulus instance: a. Place a stimulus part in your schematic from the part set: VSTIM, ISTIM, and DIGSTIMn. b. Click the VSTIM, ISTIM, or DIGSTIMn instance. c. From the Edit menu, choose Properties. d. Click the Implementation cell, type in the name of the stimulus, and click Apply. e. Complete specification of any VSTIM or ISTIM instances by selecting Properties from the Edit menu and editing their DC and AC attributes. Click the DC cell and type its value. Click the AC cell, type its value, and then click Apply. f. Close the property editor spreadsheet. 7. To change stimulus references globally for a part: a. Select the part you want to edit. b. From the Edit menu, choose Part to start the part editor.

Articles in this issue

view archives of PSpice User Guide - PSpice User Guide