PSpice User Guide Transient analysis October 2019 542 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. 9. Set up the parametric sweep and other analyses: a. From the PSpice menu, choose Edit Simulation Profile, and select the Parametric Sweep option. b. Select Global Parameter in the Swept Var. Type frame. c. Select Linear in the Sweep type frame. 10. Enter AMP in the Parameter name text box. 11. Specify values for the Start Value, End Value, and Increment text boxes. You can now set up your usual Transient, AC, or DC analysis and run the simulation. Creating new stimulus symbols 1. Use the Capture part editor to edit or create a part with the following properties: Property Value Implementation Type PSpice Stimulus Implementation Name of the stimulus model STIMTYPE Type of stimulus; valid values are ANALOG or DIGITAL; if this property is nonexistent, the stimulus is assumed to be ANALOG