Issue link: https://resources.pcb.cadence.com/i/1180526
PSpice User Guide Simulation examples October 2019 125 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. 5. Under Options, select Parametric Sweep and enter the settings as shown below. Figure 2-26 Parametric simulation settings This profile specifies that the parameter Rval is to be stepped from 100 to 10k logarithmically with a resolution of 10 points per decade. The analysis is run for each value of Rval. Because the value of R1 is defined as {Rval}, the analysis is run for each value of R1 as it logarithmically increases from 100Ω to 10 kΩ in 20 steps, resulting in a total of 21 runs. 6. Click OK. 7. From the PSpice menu, choose Run to start the analysis.