PSpice User Guide

PSpice User Guide

Issue link: https://resources.pcb.cadence.com/i/1180526

Contents of this Issue

Navigation

Page 259 of 884

PSpice User Guide Creating and editing models October 2019 260 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. 6. Save the model. The LOCAL_LIB.PRP file will be updated with the smoke information. The smoke parameters added in this example are valid for all levels. Even if you delete OPA_LOCAL_3 from the LOCAL_LIB library, the LOCAL_LIB.PRP will not be deleted because it contains smoke information for OPA_LOCAL_1 and OPA_LOCAL_2. Smoke parameters Using the Model Editor, you can add smoke information to the device types supported by the Model Editor. When you add smoke information to a device, the following two frames are displayed in the Model Editor. ■ Test Node Mapping In this section you specify the port name that must map to the predefined node names. The predefined terminal names starting with TERM indicate current nodes, and those starting with NODE indicate voltage nodes. ■ Smoke Parameters IMINUS .05 IOUT .04 VDIFF 32 VSMAX 32 VSMIN -.3 VPMAX .3 VPMIN .3 VMMAX -1.5 VMMIN .3 Table 4-6 Modified value of smoke parameters Device Max Ops Value

Articles in this issue

view archives of PSpice User Guide - PSpice User Guide