PSpice User Guide Measurement expressions October 2019 776 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. Measurements overview Measurement expressions evaluate the characteristics of a waveform. A measurement expression is made by choosing the waveform and the waveform calculation you want to evaluate. The waveform calculation is defined by a measurement definition such as rise time, bandpass bandwidth, minimum value, and maximum value. For example, if you want to measure the risetime of your circuit output voltage, use the following expression: Risetime(v(out)) For a list of the PSpice measurement definitions, see Measurement definitions included in PSpice on page 786. You can also create your own custom measurement definitions. See Creating custom measurement definitions on page 790 in the Power Users section of this chapter.