Issue link: https://resources.pcb.cadence.com/i/1180526
PSpice A/D User Guide Analyzing waveforms October 2019 726 Product Version 17.4-2019 © 2022 All Rights Reserved. can then view each part separately in the PSpice A/D probe window. See the figure below. Number of parts into which the complete trace can be divided is governed by the number of data points in the trace. For example, if a complete trace has 4.5 million data points, and at any given point of time PSpice A/D is configured to load only 1 million data points, the complete trace will be divided into 5 parts. First four part traces will be of 1 million data points each and the last part trace will be of 500000 data points. The size of the partial trace is also influenced by the number of data points per part. By default, the limit is set to 1 million data points per Complete Trace Complete trace broken in 5 parts Part 1 of the trace Part 2 of the trace Part 3 of the trace Part 4 of the trace Part 5 of the trace Figure 17-3 Displaying partial traces