PSpice User Guide Monte Carlo and sensitivity (worst-case) analyses October 2019 593 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. Worst-case analysis example The schematic shown in Figure 13-11 is for an amplifier circuit that is a biased BJT. This circuit is used to demonstrate how a simple worst-case analysis works. It also shows how non-monotonic dependence of the output on a single parameter can adversely affect the worst-case analysis. Because an AC (small-signal) analysis is being performed, setting the input to unity means that the output, Vm([OUT]), is the magnitude of the gain of the amplifier. The only variable declared in this circuit is the resistance of Rb2. Because the value of Rb2 determines the bias on the BJT, it also affects the amplifier's gain. Figure 13-11 Simple biased BJT amplifier. Figure 13-11 is the circuit file used to run one of the following: ■ a parametric analysis (.STEP, shown enabled in the circuit file) that sets the value of resistor Rb2 by stepping model parameter R through values spanning the specified DEV tolerance range, or