PSpice User Guide Monte Carlo and sensitivity (worst-case) analyses October 2019 559 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. 4. Select the MC Load/Save button. 5. In the Load/Save Monte Carlo Parameter File dialog box, select the Save Parameter values in filename: check box. 6. In the text box that is enabled, specify the name and the location of the file in which the parameter data is to be saved. 7. Click OK to save your settings. If you now run the Monte Carlo analysis, the model parameter values used for various simulation runs will be stored in the .mcp file specified by you.