PSpice User Guide Parametric and temperature analysis October 2019 518 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. Troubleshooting tip More than one PSpice run or data section is required for performance analysis. Because one data value is derived for each waveform in a related set of waveforms, at least two data points are required to produce a trace. Use Evaluate Measurement (from the Trace menu) to evaluate a measurements on a single waveform and produce a single data point result.