Issue link: https://resources.pcb.cadence.com/i/1180526
PSpice A/D User Guide Creating and editing models October 2019 221 Product Version 17.4-2019 © 2022 All Rights Reserved. The schematic page editor searches the model libraries for the instance model. To find out how design entry tools searches the library, see Changing model library search order on page 255. ❑ If found, the schematic page editor starts the Model Editor, which opens the design library and loads the instance model. ❑ If not found, the schematic page editor assumes that this is a new instance model and does the following: makes a copy of the original model definition in the DESIGN_NAME.LIB and starts the Model Editor with the new model loaded. After you start the Model Editor, you can proceed to change the text as described in To display the model text on page 239. Saving design models When you save your edits, the following is done for you to make sure the instance model is linked to the selected part instances in your design: ■ The Model Editor saves the model definition to DESIGN_NAME.LIB. ■ If the library is new, the Model Editor configures DESIGN_NAME.LIB for local use. The schematic page editor assigns the new model name to the Implementation property for each of the selected part instances (see What happens if you do not save the instance model on page 222). To save instance models 1. From the File menu, choose Save to update DESIGN_NAME.LIB and save it to disk. Actions that automatically configure the instance model library for global use Instance model libraries are normally configured for design use. However, if you perform the following action, the Model Editor configures the library for global use instead: