PSpice User Guide

PSpice User Guide

Issue link: https://resources.pcb.cadence.com/i/1180526

Contents of this Issue

Navigation

Page 182 of 884

PSpice User Guide Preparing a design for simulation October 2019 183 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. then you may be missing a model library, stimulus file, or include file from the configuration list, or the configured file is not on the library path. Check for this ■ Does the PSpice library configuration file NOM.LIB appear in the Library files list in the Configuration Files tab in the Simulation Profile? ■ Does the relevant model library, stimulus file, or include file appear in the configuration list? ■ If the file is configured, does the default library search path include the directory path where the file resides, or explicitly define the directory path in the configuration list? If the file is not configured, add it to the list and make sure that it appears before any other library or file that has an identically-named definition. To find out more about how to configure these files and about search order, see Configuring model libraries on page 244. To find out more about the default configuration, see How are models organized? on page 190. To view the configuration list 1. In the Simulation Settings dialog box, click the Configuration Files tab and view the Library, Include, and Stimulus files lists. If the directory path is not specified in each, update the default library search path or change the file entry in the configuration list to include the full path specification. To view the default library search path 1. In the Simulation Settings dialog box, click the Configuration Files tab. 2. Click Library in the Category field to display the Library files list. To find out more about the library search path, see Changing the library search path on page 253.

Articles in this issue

view archives of PSpice User Guide - PSpice User Guide