PSpice A/D User Guide Monte Carlo and sensitivity (worst-case) analyses October 2019 577 Product Version 17.4-2019 © 2022 All Rights Reserved. Temperature considerations in statistical analyses The statistical analyses perform multiple runs, as does the temperature analysis. Conceptually, the Monte Carlo and worst-case loops are inside the temperature loop. However, since both temperature and tolerances affect the model parameters, OrCAD recommends not using temperature analysis when using Monte Carlo or worst-case analysis. Also, you cannot sweep the temperature in a DC sweep analysis or put tolerances on temperature coefficients while performing one of these statistical analyses. In EXAMPLE.OPJ, the temperature value is fixed at 35 ° C.