Migration Guide for Allegro Platform Products Allegro Platform High Speed Products October 2019 125 Product Version 17.4-2019 © 1999-2019 All Rights Reserved. Migration-Related Information for Release 16.2 Net Extraction in HDI Designs When extracting a net in a high-density interconnect (HDI) design, do not model vias as analytical (FSvias) if the design you are extracting from has no plane layers. Under such conditions, select Closed Form mode. To enhance the accuracy of extractions in the MGH range, we recommend using a 3-D field solver from a member of the Cadence Connections program. PakSI-E 3-D Field Solver Non-legacy versions of Package SI And SiP Digital SI no longer come equipped with the PakSI-E 3-D field solver. In order to use this modeling capability with non-legacy products, you must license the field solver from Apache © Design Solutions and install it separately. You can then run PakSI-E through Package SI and SiP SI, as in previous releases. If you are running the legacy versions of SI, PakSI-E continues to operate as in the legacy version of release 16.01.