Click OK, then all the rows for that constraint set (SCS1_POWER_GROUP) get set to 0.2 mm. Now we can apply the constraint set to the Spacing >Net > All Layers worksheet by selecting it from the dropdown options shown below and applying it to the POWER_GROUP. Standard Manufacturing Constraints Now in the Manufacturing section we have many checks to consider: Design for Fabrication f Outline f Mask f Annular Ring f Copper Features f Copper Spacing f Silkscreen Design for Assembly f Outline f PkgToPkg Spacing f Spacing f Pastemask 32 www.cadence.com OrCAD X Constraint Management Guide