Allegro Constraint Compiler: Workshop Learn more at Cadence Support Portal - https://support.cadence.com © 2019 Cadence Design Systems, Inc. All rights reserved w orldw ide. Page 72 design. Type=Intra-Group specifies the Rule Specification and Rule Set to drive Spacing rules within the Type SATA_BANKS groups. Type= SATA_BANKS specifies the Type classification for the RX/TX Net Diff Pairs defined, grouped by unique Net Group name, in the Object table. The Rule Specification and Rule Set specified in this column drive Spacing rules to Type SATA_BANKS groups. 13. Save the changes; then select File > Save As to save the spreadsheet in CSV format under the same filename using the file type CSV (Comma delimited) (.csv). 14. Open Constraint Manager and select Tools > Constraint Compiler. 15. Select the acc_library and ACC_Workshop_mapping.csv folders. 16. Click the Load Selected Files button. 17. Double-click on Interface and Table Type under the Keys pane. 18. Select Interface under the Query Filter pane and change the Value under the Define Query Filter pane to SATA.