Enabling CM on Existing Schematic Design with Constraint Added in PCB Layout: RAK
Learn more at Cadence Support Portal - https://support.cadence.com
© 2019 Cadence Design Systems, Inc. All rights reserved w orldw ide. Page 20
Figure 22: Min Max Propagation Delays
6. As shown in Figure 22, do the following:
a. In the From and To input box, enter the U3.11 and U4.1 values,
respectively.
b. Define Min Delay as 9 ns.
c. Define Max Delay as 15 ns.
d. Click the Add button.
e. The newly added rule will be seen in the Existing Rules field.
f. Click OK to close the dialog box.
7. Select File > Update Constraint Manger to add this constraint to the CM UI.