Allegro/OrCAD Rigid Flex Design Creation Best Practices _______________________________________________________________________ Learn more at Cadence Online Support - https://support.cadence.com Page 43 © 2016 Cadence Design Systems, Inc. All rights reserved worldwide. 1 inside 2 D RC Vio latio n When two objects on different subclasses must have matching outlines, such as a Gold Mask on a Component Pin, the Inside check may also be used. To set the exact outline match, the value for the check is set to "0.00". The rule is defined as category Via (and Pin), and TOP and GOLD_SOFT_TOP subclasses are selected. The 2 Inside 1 rule type is set with a value of 0.00. The "M" character is used to represent mask. The DRC is displayed on the ETCH/TOP subclass. A note is also added. D efinin g 2 Insi de 1 fo r geo m etry o utline m atch When the two subclasses are checked, the DRC violation is displayed,