Enabling CM on Existing Schematic Design with Constraint Added in PCB Layout: RAK
Learn more at Cadence Support Portal - https://support.cadence.com
© 2019 Cadence Design Systems, Inc. All rights reserved w orldw ide. Page 10
Module 2: Buses and Net Groups in Capture CM
In Capture CM UI, bus objects like buses and buses created in Capture due to net
group will not be supported in the Capture CM flow. However, if there are bus objects
existing in the PCB layout, they will be migrated when you migrate the constraints from
the PCB layout at the time of CM enablement of the design. The buses that are
migrated to Capture CM will be transferred to the board only when the user performs
an ECO with the existing board.
After completing Module 1, do the following steps:
1. Launch Constraint Manager.
Figure 10: Buses and net group buses
2. In the schematic page "pg1_main", observe the buses and net group buses in
the Capture design. These correspond to the Q[0..7] bus and the MC[0..15] net
group in Capture.