Enabling CM on Existing Schematic Design with Constraint Added in PCB Layout: RAK
Learn more at Cadence Support Portal - https://support.cadence.com
© 2019 Cadence Design Systems, Inc. All rights reserved w orldw ide. Page 8
7. The Design Sync window will launch from Schematic to Layout. Click Sync.
Figure 6: Schematic to Layout Design Sync
Note:
• When the design becomes CM-enabled, all constraints assigned as
properties from the property sheet editor will get transferred to Constraint
manager gui.
• As shown in Figure 6, during the CM enablement steps:
o To complete the Constraint migration, run Design sync:
▪ Schematic to Layout
▪ Layout to Schematic
8. Constraint migration report will be generated to show the list of migrated
constraints and objects. Also, PCB Editor will launch with the board.