Page 22 of 28

10. If you scroll to the right, you will see all the fields populated, and the Min BB Via Gap value is already set (see image below). Now that the spacing constraint set has been created for any object in the BGA Region/area, we are ready to apply it to said region. 11. In CM, return to the left section Spacing - Region - All Layers to open the worksheet shown below. 12. Let's assign our new spacing constraint set to this BGA-REGION by clicking the cell in the column named Referenced Spacing CSet and choosing SCS_BGA-REGION. 13. Notice that all the cells (values under every column) get populated with the spacing rule we set just earlier (3 mils = 0.076 mm). 23 www.cadence.com Part 1 of 5