Page 10 of 28

15. The Create PhysicalCSet window appears (seen below). 16. In the PhysicalCSet field, name it POWER1, then click OK. The window closes. 17. Next, we assign this POWER1 rule to this entire class by clicking the dropdown list to the right of the POWER(6) cell (click DEFAULT shown below), then select POWER1. 18. Now, at any time, we can go to the POWER1 Physical Constraint Set in CM and set any values we want to all those traces within the Power net class we created earlier. 19. To do the constraint update (see below), while still in the Physical worksheet in CM, choose Physical Constraint Set folder - All Layers. That will make the worksheet visible on the right. 20. Scroll down that worksheet to find POWER1. Expand it by clicking the triangle. 11 www.cadence.com Part 1 of 5