Allegro/OrCAD Rigid Flex Design Creation Best Practices _______________________________________________________________________ Learn more at Cadence Online Support - https://support.cadence.com Page 40 © 2016 Cadence Design Systems, Inc. All rights reserved worldwide. Overlap The overlap rule is used to ensure that one item overlaps another by a minimum amount. For example, a transition area must overlap a zone boundary by 2.54mm. To enable an Overlap rule: 1. Select the TRANSITION_ZONE and ZONE_OUTLINE subclasses. 2. Select the rule type as Overlap. 3. Define the overlap value. 4. Assign a DRC label. For example, choose "T" for Transition. 5. Assign the DRC Display Layer. D efinin g an Ov erla p Rul e When the user adds a transition area geometry and violates the overlap rule, a DRC marker is displayed indicating the overlap value has not been met.