Getting Started with Symphony Team Design Getting Started with Symphony Team Design October 2019 72 Product Version 17.4-2019 5. Placement rearrangement complete, ready for routing. Symphony Window – Locks Tab This tab displays objects that have been locked by connected clients. Permanent object locks explicitly set by the client to prevent other clients from interacting with the objects. Any client locks are cleared once they disconnect from the session. Lock tab entry label = [Perm] You can add permanent object locks as follows: ■ Select object, right-click and choose Multi-User Lock. ■ Choose File – Edit – Multi-User Lock and select objects. To release permanent locks right-click and choose Multi-User UnLock or select File – Edit – Multi-User UnLock menu option. You can also release object locks from the Lock tab of Symphony server window. Note: Locks are automatically released when the client disconnects from the Symphony server application.