Working with Backdrilling in Allegro PCB Designer: Best Practices Learn more at Cadence Online Support https://support.cadence.com © 2014 Cadence Design Systems, Inc. All rights reserved worldwide. Page 48 NC Drill Legend dialog In the following figure, the NC Drill Legend accounts for all the sites to be backdrilled from the layer BOTTOM through the layer LAYER_9_P into the dielectric layer between LAYER_9_P and LAYER_8. The actual depth range into the dielectric material might vary from vendor to vendor because there are many fabrication tolerances to consider. Hence, Cadence makes no effort to supply controlled depth data but provides depth to the surface of the Must Not Cut Layer for reference.