Analysis Workflows: Reflections Analysis (RAK)
Learn more at Cadence Support Portal - https://support.cadence.com
© 2019 Cadence Design Systems, Inc. All rights reserved w orldw ide. Page 11
Reflection Analysis Setup
16. Click the Select Nets link under the Setup for Analysis section of the Analysis
Workflows pane. This opens the (X)Net Selection dialog. Select five nets as
shown below from the Available (X)Nets section to the Selected (X)Nets
section. Click OK.
17. Select the Analysis Options link under the Setup for Analysis section of the
Analysis Workflows pane. This opens the IDA Reflection Analysis Parameter
Setup dialog. You can modify various parameters at the top to impact all nets in
the selection or at the bottom to change parameters for individual nets. Set the
Offset/Delay for all nets to 1ns. Click OK.
18. Select the Start Analysis link under the Analysis section of the Analysis
Workflows pane to run reflection analysis. Once the analysis is completed, the
Save Analysis Results, Reflection Table, and Reflection Vision links get
enabled.